FIRE ALARM SYSTEM

Fire Alarm And Protection Systems

An automatic fire alarm system is designed to detect the 

unwanted presence of fire by monitoring environmental changes 

associated with combustion. In general, a fire alarm system is 

either classified as automatically actuated, manually actuated, 

or both. Automatic fire alarm systems can be used to notify 

people to evacuate in the event of a fire or other emergency, to 

summon emergency services, and to prepare the structure and 

associated systems to control the spread of fire and smoke.

There are many types of fire alarm systems each suited to 

different building types and applications. A fire alarm system can 

vary dramatically in both price and complexity, from a single 

panel with a detector and sounder in a small commercial property 

to an addressable fire alarm system in a multi-occupancy building. 

Systems have to protect both buildings and occupants.

Teso Tech Ltd has earned a reputation in fire safety 

engineering. Our designs employ detailed components, 

arrangements and interfaces to meet and exceed the minimum 

levels of protection mandated by appropriate model building 

code, insurance agencies and other authorities.

Design equipment specifically manufactured for fire engineering are selected and 

standardized installation methods are anticipated during the design.

Secondary (backup) power supplies consisting of sealed lead-acid storage batteries are 

used to supply energy in the event of a primary (electric) power failure.

Specific industrial designs are available that allow the fire alarm system to control aspects 

of the built environment and to prepare the building for fire and to control the spread of 

smoke fumes and fire by influencing air movement, lighting, process control, human 

transport and exit.

Manually actuated devices such as break glass switches, buttons and manual pull stations 

are installed to be readily visible and located near the exits for identification and operation.

Sensors we use include heat detectors, smoke detectors, flame detectors, carbon 

monoxide detectors depending on the location and environment protected.

Newest innovations use cameras and computer algorithms to analyze the visible effects of 

fire and movement in applications inappropriate for or hostile to other detection methods.

Alarms and alerts include audible, visible, tactile, textual or even olfactory stimuli 

(odorizer) installed to alert the occupants and configured to avoid confusion with other 

signals using similar sounding appliances.

In some designs, active fire protection (AFP) is an integral part of fire protection and 

involves the use of fire suppression and extinguishing devices triggered automatically by 

fire detection. AFP often employs automatic water sprinkler system, gaseous 

clean agent, or fire fighting foam system usually found in large commercial kitchens, 

petrochemical plants and or other high-risk areas. AFP works alongside modern 

architectural designs and construction materials and fire safety education to 

prevent, retard, and suppress structural fire.

Manual fire fighting equipment such as fire extinguishers (stored pressure, 

cartridge-operated, handheld, cart-mounted/wheeled types) and Standpipe (hydrant hose 

reel) systems are available. Cart-mounted/wheeled models are most commonly used in 

construction sites, airport runways, heliports, docks and marinas.

Internet protocol (IP) fire alarm and protection systems are available for monitoring and 

controlling fire incidents over the internet. 

Our experience over the years enables us make good choice of quality materials to avoid 

issues like false alarms and failures.

Systems we install also have added features that automatically dial (and send SMS to) 

preset numbers once fire is detected. The systems can be programmed during installation 

to dial the fire stations and authority as well as other numbers selected by user.

We also handle repairs, maintenance and upgrade of existing systems.

TESO TECH LIMITED(ICT Solutions provider)

Email:info@tesotechservices.com

Tel: +234-907-7253070,+234-817-6969812

Mobile /WhatsApp: +234-907-7253070

website: http://tesotechservices.com/products

Head office Address: KM 4 Benin Sapele Road,Oposite Baden-Baden Motel,Inside NNPC Petrol station,Benin City,Edo State,Nigeria

Benin Branch Office:No 68 Akpakpava street,after first Bank plc 

Warri Branch office:Favour Bakery Along Aka Avenue, through Refinery road, after Apribet Filling Station ,Effurun,Warri, Delta State

Lagos Branch office:Km 47,Lekki-Epe express way, Majek Bus stop, inside NNPC fillings station. Lagos

DELIVERY AND INSTALLATION IN NIGERIA AND BEYOND.

Thanks

Sales Representative

Teso Tech Limited